Permit: T00CM05937

Parcel: 115022700

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
03/17/2003 BUILDING - FINAL Approved IVRS - Inspection 0000*
03/29/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) CLEANOUTS REQUIRE THREADED CAPS AND TRIM RISERS TO GRADE 2) OUTSIDE HOSE BIBS REQUIRE ANTI-SIPHON VALVES 3) VANITY MISSING GFCI 4) RANGE PLUG MUST BE 4 WIRE GROUNDED 5) DISH WASHER DRAIN MUST LOOP TO WITHIN 2" OF FLOOD RIM OF SINK OR INSTALL AIR GAP 6) PENSULA REQUIRES GFCI OUTLET
12/31/2001 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*