Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T00CM05921
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/21/2001 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000* | |
06/07/2001 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection 0000*CANCELLED BY APPLICANT. | |
05/31/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999*1)THE WIRING WHERE YOU SPLICED IN SUPPLY CORD IS OK.2)IN SUBPANEL YOU MAY NOT HAVE MORE THAN 2 GROUND WIRES OF EQUAL SIZE UNDER 1 LOG.3)ALL OUTLETS, RECEPTACLES, FIXTURES, SWITCHES AND SMOKE DETECTORS MUST BE IN PLACE BEFORE FINAL.4)BATHROOM, KITCHEN COUNTER AND EXTERIOR OUTLETS ARE REQUIRED TO BE GFI TYPE OUTLETS.5)HOME WILL HAVE TO BE RE-BLOCKED (LEVELED) AND MINIMUM HOUSING ISSUES ADDRESSED BEFORE ELECTRICITY IS ALLOWED TO BE TURNED ON. |