Permit: T00CM05896

Parcel: 107150460


Addresses:

444 E GLENN ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
09/17/2001 BUILDING - FINAL Approved IVRS - Inspection 0000*
09/10/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) #3 AND #6 FROM PREVIOUS INSPECTION 9/5/01
09/05/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) BARE BULB LIGHT FIXTURES NOT ALLOWED IN CLOSETS 2) 3 OUTLETS IN EAST BEDROOM HAVE HOT NEUTRAL 3) BATH GFCI HOT WHEN TRIPPED OR BAD UNIT 4) OUTSIDE ELECTRIC OUTLETS MUST BE GFCI PROTECTED 5) ONE EXIT CANNOT BE DOUBLE KEY LOCKED 6) KITCHEN COUNTER MUST BE GFCI PORTECTED