Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 04/30/2001 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 04/27/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0935*/ NOT COMPLETE, RE-FEE |
| 04/26/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1) ROOF TOP MAINTENANCE OUTLET MUST BE GFCI PROTECTED 2) COOLER (TUCSON BOX) AND MAINTENANCE OUTLETS CANNOT BE SUPPORTED BY A SINGLE CONDUIT, INSTALL ADDITIONAL SUPPORT 3) OUTSIDE ELEC OUTLET MUST BE GFCI PROTECTED 4) BOX AROUND LAUNDRY DRAIN OUTSIDE TO PROTECT 5) ITEMS 7, 8, AND 11 FROM 4/20/01 NOT COMPLIED WITH 6) KITCHEN MUST BE ON 2-20 AMP CIRCUIT FOR COUNTER 7) ALL KITCHEN COUNTER OUTLETS MUST BE GFCI PROTECTED 8) ELECTRIC SRVC ENTRANCE MUST BE PROPERLY SECURED AND SEALED BY TEP |
| 04/20/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1) ABS PLASTIC VENTS ON ROOF MUST BE PROTECTED WITH LATEX PAINT 2) OUTSIDE ELEC OUTLETS MUST BE GFCI PROTECTED 3) ROOF TOP ELEC OUTLET MUST BE GFCI PROTECTED 4) WASTE VENTS WITHIN 10 FEET OF EVAP COOLER MUST EXTEND A MIN OF 1 FOOT ABOVE COOLTER 5) ROOF T CAP VENTS MUST HAVE 1/4" OR SMALLER MESH SCREEN 6) ABS LAUNDRY WASTE LINE NOT ALLOWED ON EXTERIOR OF BLDG OR INSTALLED WITHIN 12" OF GRADE 7) FILL KNOCK OUTS IN ELEC PANEL 8) LABLE ALL CIRCUITS IN ELEC PANEL 9) HOSE BIBS REQ ANTISIPHON VALVES 10) ELEC PANEL TEP SEAL BROKEN 11) KITCHEN COUNTER OUTLETS MUST BE GFCI PROTECTED 12) LAUNDRY ROOM LOCKED 13) PROVIDE INSULATION INSTALLED CERTIFICATE 14) UNUSED GAS LINE MUST BE CAPPED (RANGE) |