Permit: T00CM05870

Parcel: 137339070


Addresses:

1956 W BAGLEY WY

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/08/2001 FRAMING Approved IVRS - Inspection 0000*
03/07/2001 FRAMING Partial Approval IVRS - Inspection 0000*/1. DETIAL 6/SD2 IN PROGRESS. 2. NAIL 2ND FLOOR SOLE PLATE 12" OC. 3. POST UNDER 2 X 12 BOTH SIDES . 4. ALTERNATIVE HOLDOWN AT ENTRY NOT IN STALLED. 5. PROTECT CONDENSATE LINE WITHIN 1 1/4 FROM EDGE OF SOLE PLATE AND DBL TOP PLATE.
03/05/2001 FRAMING Denied IVRS - Inspection 0999*/1. INSULATION AT GARAGE ENTRY LID NOT INSTALLED. 2. SUPPORT REQUIRED UNDER VTR 90 DEGREE ANGLES. 3. HOLDOWN IN FRONT NOT INSTALLED "ALTERNATIVE METHOD". 4. PROTECT ABS 45 DEGREE ANGLE BEHIND GARAGE OSB WALL. 5. PROVIDE TWO ANCHOR BOLTS AT SOLE PLATE SUPPORTING GLU LAM. 6. HEADER IN BATHROOM ENTRY FIRST FLOOR NOT COMPLETE. 7. SECURE SINGLE GIRDERS AS PER PLAN POST AND TIES.