Permit: T00CM05861

Parcel: 119031290


Addresses:

708 W 41ST ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/24/2001 FRAMING Approved IVRS - Inspection 0000*
01/23/2001 FRAMING Denied IVRS - Inspection 0999*/MISSING ANCHOR BOLTS ON BOTTOM PLATES BLOCK 3 SIDES ON MECH DUCT.
01/18/2001 FRAMING Denied IVRS - Inspection 0999*/1. MISSING ANCHOR BOLTS ON SILL PLATES (FROM PRIOR INSPECTION) 2. STUD MISSING BETWEEN BATH. 3. NO TEST ON PLUMBING. 4. BLACK 3 SIDES ON MECH DUCT FRONT BEDROOM
01/16/2001 FRAMING Denied IVRS - Inspection 0925*/1. STUD MISSING BETWEEN BATHS. MAX SPAN ALLOWED 24" 2. A MINIMU OF 2 ANCHOR BOLTS REQUIRED IN EACH SILL PLATE. WITHIN 12" OF ENDS AND SPLICES. 3. FILL GAPS BETWEEN HEADERS AND DOUBLE TOP PLATES DOUBLE TOP PLATES SAGGING. 4. GAS GAUGE STICKS REPLACE. NO PLANS OR PERMIT FOUND STOPPED INSPEC.