Inspection Status: Denied
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/06/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/HAVE LICENSED ELECTRICIAN PROVIDE CODE REQUIREMENTS. 1. BOND WIRE FOR COPPER AND GAS LINE NEEDS TO BE CONNECTED AT PANEL NUETRAL BAR. 2. ANCHOR BOLTS NOT INSTALLED PER UBC SEC. 1606. 3. CONCEAL ALL ELEC. WITHIN 8' FROM FLOOR. 4. PROVIDE GFCI RECEP. AT EXTERIOR OR GFCI CIRCUIT BREAKER AT PANEL. 5. PROVIDE 1" CLEARANCE FROM HOT WATER FLUE PIPE TO COMBUSTIBLE MATERIAL. |
| 01/08/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/1. UNABLE TO INSPECT TOO MANY ITEMS INCLOSET AREAS. 2. PROVIDE ANCHOR BOLTS. 3. CONCEAL ALL ELEC ROMEX UNDER 6'8" 4. PROVIDE BOND TO GAS LINE AND WATER LINES NEED TO BE ACCESSIBLE. 5. PROVIDE SMOKE DETECORS ALL BEDROOMS AND ENTRY HALLWAY TO SLEEPING QUARTERS. |
| 12/29/2000 |
FRAMING |
|
Not ready for Inspection |
|