Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T00CM05835

Parcel: 141152270

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
01/11/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
01/10/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. ROOF PANELS MISSED ROWS ON A FEW PANELS, 1 TO 2 ROWS DOWN FROM RIDGE, NEAR HIP. 2. MISSED TRUSSES WITH STAPLES, EAST SIDE NEAR REAR SEE SHINERS. 3. MISSING STUD CLIPS AT FRONT ENTRY. 4. MISSING HEADER STRAPS AT FRONT ENTRY. 5. INSTALL ALTERNATE HOLDOWN AT REAR WINDOW.