Permit: T00CM05817

Parcel: 136382000


Addresses:

7272 E OLIVE PL

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
01/19/2001 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection 0000*/NOTE: ROLL COMBO UP UPPER 1/3 OF HORIZ. PIPE VENT FOR TOLIET. USE COMBO NOT SAN-TEE VENT FOR SHOWER.
01/18/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval 1. TOILET VENT MINIMUM 2". 2. SAN TEE'S USED BELOW GRADE A VENTS NOT TO BE IN HORIZ. POSITION USE COMBO FITTINGS 3. WHEN GOING VERTICAL TO HORIZ. USE LONG SWEEP 90 DEGREE'S DRAINAGE ONLY AT LAV.