Permit: T00CM05815

Parcel: 137117870


Addresses:

5637 S BALLANTRY DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/08/2001 FRAMING Approved IVRS - Inspection 0000*
02/07/2001 FRAMING Denied IVRS - Inspection 0999*/1. FLUE PIPE BENT TURN THEM INTO SINGLE WALL. 2. PROTECTIVE PLATES AT WATER LINE AT BLOCKING AND ELECT. AT N. WALL BEHIND SINK.
02/01/2001 FRAMING Denied IVRS - Inspection 0999*/1. SECURE GAS LINES THRU OUT SEE UNIFORM PLUMBING CODE TABLE 12-2. 2. SECURE PEX 4' O.C. THRU OUT SEE MANF. SPEC'S 3. PROTECT WATER LINES IN HALL BATH. 4. PROVIDE 1" CLEARANCE AT HOT WATER FLUE PIPE AND FURNACE FROM WEB. 5. FIRE BLOCKS MISSING LOWER CEILING HEIGHT AT MASTER BEDROOM AND NORTH EAST CORNER. SECURE SOLE PLATE AT PARTITION WALL AND FHA STRAP.