Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/30/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 01/29/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/PREVIOUS INSPECTION REQUEST ON 1/23/01 NOT COMPLIED WITH SEE NOTE #1 A REINSPECTION FEE WILL BE IMPOSED ON ALL INSPECTIONS FOR SHEATHIN WITHOUT 1/8" GAP AT PANEL ENDS AND EDGES LEAVE BACK WALL EXPOSED. |
| 01/25/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/PROVIDE STRAPS AT REAR GABLE |
| 01/23/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1. PROVIDE 1/8" GAP AT SHEARWALLS OSB. 2. SECURE GABLE END TRUSS TO DBL TOP PLATE. 3. SECURE HEADERS OVER 5' DIAGONAL. 4. CLIPS MISSING THRU OUT. |