Permit: T00CM05753

Parcel: 141085320

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
02/03/2001 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection 0000*
02/01/2001 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000*
NO NOTES
01/31/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval FOOTING, PARTIAL
TWO F-4'S AT EQUIPMENT LOG AND SHOWER 115
TWO F-6'S AT NORTH EAS CORNER OF TRAINING 117 AND N.W. CORNER OF CONFER 102
ONE F-7 AT STAIR LANDING
01/28/2001 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
EAST, WEST AND SOUTH PERMETER FOOTINGS
01/25/2001 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000*
COMPLETE EXC. (FLAT BOTTOM AND CLEAN)
COMPLETE STL.