Permit: T00CM05710

Parcel: 141112840

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T00CM05710

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
01/26/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
01/25/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. LOOSE ROOF PANEL AT GARAGE W. SIDE. 2. PLAN CALLS FOR SHEAR STRAPS AT 48" O.C. (SEE DETAILS 7/SD3 AND 6/SD3). (AT BEAM INTERSECTIONS ABOVE STAIRS, INCORRECT HANGERS WERE USED. MUST BE CHANGED TO LUS 210-2 PER PLAN IN ORDER TO PASS INTERMEDIATE INSP.)
01/24/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. LOOSE ROOF PANELS-BOTH LEVELS. 2. SOUTHWEST 2ND FLOOR SHEARWALL NOT NAILED AT CORNER. 3. FLOOR TRUSS BRACKETS NOT NAILED. 4. STRAP OUTSIDE OF PLATES ABOVE SLIDING GLASS DOORS BOTH LEVELS. 5. PUT MORE NAILS IN BENT OVER BRACKET FOR HIP TRUSS. 6. PROVIDE ALTERNATE HOLDOWN WHERE MISSED AT NORTH WINDOW.