Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T00CM05705

Parcel: 133243950

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T00CM05705

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
01/22/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
01/17/2001 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/COMPLETE ITEMS-1. INSTALL BANG PLATES AT PLB. PENETRATIONS. 2. NAILS TOP AND BOTTOM WIND BRACING. 3. INSTALL ROOF FASTNERS.
01/11/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. INSTALL BRACING AND CLIPS PER DETAIL 2/A5. 2. INSTALL BANG PLATES AT PLB PENETRATIONS. 3. 2 NAILS TOP AND BOTTOM WIND BRACING 4. SPLICE IN BRACING TO SPAN A MIN. 2 STUD SPACES ( 3 STUDS) 5. INSTALL SOLID WOOD BEAM HEADERS WHERE INDICATED. 6. CROSS BRACE TRUSSES MAX. 25' OF RUN. 7. SEE DETAIL 3/A8 AT FRONT ENTRY AND COMPLY. 8. RENAIL PLYWOOD WHERE BUCKLED. 9. INSTALL ROOF FASTNERS FLUSH WITH SHEATHING. 10. SUPER TO WALK ALL JOBS AND CORRECT NECESSARY ITEMS PRIOR TO CALLING FOR INSPECTION.