Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T00CM05705
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/22/2001 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
01/17/2001 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*/COMPLETE ITEMS-1. INSTALL BANG PLATES AT PLB. PENETRATIONS. 2. NAILS TOP AND BOTTOM WIND BRACING. 3. INSTALL ROOF FASTNERS. | |
01/11/2001 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/1. INSTALL BRACING AND CLIPS PER DETAIL 2/A5. 2. INSTALL BANG PLATES AT PLB PENETRATIONS. 3. 2 NAILS TOP AND BOTTOM WIND BRACING 4. SPLICE IN BRACING TO SPAN A MIN. 2 STUD SPACES ( 3 STUDS) 5. INSTALL SOLID WOOD BEAM HEADERS WHERE INDICATED. 6. CROSS BRACE TRUSSES MAX. 25' OF RUN. 7. SEE DETAIL 3/A8 AT FRONT ENTRY AND COMPLY. 8. RENAIL PLYWOOD WHERE BUCKLED. 9. INSTALL ROOF FASTNERS FLUSH WITH SHEATHING. 10. SUPER TO WALK ALL JOBS AND CORRECT NECESSARY ITEMS PRIOR TO CALLING FOR INSPECTION. |