Permit: T00CM05688

Parcel: 110151700


Addresses:

5651 E WATER ST

Inspection Status: Partial Approval

Inspection History: STUCCO MESH

Date Description Inspector Results Comments
12/27/2000 STUCCO MESH Partial Approval IVRS - Inspection 0000*/1. YOU NEED J-METAL OR PLASTER GROUND METAL AT WALL TO FENCE AND STUCCO TO BLOCK AT FRONT VERTICAL JOINTS MUST HAVE METAL AT ENDS OF FOAM AND PLASTER. 2. AT ALL PLACES WHERE ROMEX IS CLOSER THAN 3/4 TO EDGE OF 2X PLACE A METAL PROTECTOR, SO THT DRYWALL NAIL WON'T PENETRATE WIRE 3. WILL CHECK ELECT SERVICE AT FINAL.