Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 08/28/2001 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 08/23/2001 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) WATER HEATER "B" VENT REQUIRES 1" TO COMBUSTIBLES 2) BEARING WALL STUDS NOTCHED GREATER THAN 25% 3) ELECTRIC OUTLET/JUNCTION BOXES CANNOT BE CONCEILED IN WALL 4) STRANDED WIRE MUST BE IN CONDUIT 5) PROVIDE NAME & LICENSED NUMBER OF ELECTRIC/MECHANICAL AND PLUMBING CONTRACTORS 6.) NAIL PROTECT PLUMBING & ELECTRIC WITHIN 1 1/4" OF STUD SURFACES 7) FIRE BLOCK ALL CEILING DROPS AND FURR OUT WALLS 8) ANCHOR BOLTS REQUIRED WITHIN 12" OF SILL PLATE END & SPLICES 9) PROVIDE GAS PRESSURE TEST ON WHOLE HOUSE 10) INSULATE ALL DUCT WORK PER CODE 11) MECHANICAL DUCTS DOUBLED GREATER THAN 1/3 12) WATER CLOSET FLOOR FLANGES NOT IN 13) COMPLY WITH DETAIL 8 AT GARAGE OR REVISE PLAN TO AS BUILT AND HAVE APPROVED BY CITY OF TUCSON 14) LAUNDRY FLOOR DRAIN MUST HAVE TRAP PRIMER 15) PROVIDE TJI BEARING BLOCKS AT INTERIOR BEARING WALL 16) PROVIDE TRUSS ENGINEERS APPROVAL OF SHIMMED TRUSSES 17) MECHANICAL DUCT WORK NOT PER PLAN 18) REVISE PLUMBING AND GAS PLANS TO AS BUILT |
| 08/16/2001 |
ELECTRIC - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) PROVIDE POSITIVE FLOW AT BATHROOM 2) STUDS AT BEAMING WALL OVER NOTCHED 3) SAN "T" AT SHOWER FOR VENT CANNOT BE FLAT 4) NOT READY, STOPPED INSPECTION, CALL BACK WHEN READY |