Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/24/2001 |
SHEET ROCK NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 09/21/2001 |
SHEET ROCK NAILING |
|
Denied |
IVRS - Inspection 0999*/ 1) GARAGE 5/8 TYPE CROSS MUST BE SECURED/FASTENED WITH 1 7/8" NAILS OR SCREWS SPACED AT 7" IN FIELD AND TOP AND BOTTOM PLATES CEILING MUST BE SCREWED/NAILED AT 7" ON CENTER AND HAVE EITHER 1 LAYER OF 5/8" TIPPEX OR 2 LAYERS OF 1/2" DRYWALL 2) PORCH MUST USE SOFFIT BOARD 3) HOUSE NOT COMPLETE ENOUGH TO INSPECT 4) GREEN BOARD NOT ALLOWED IN CEILING |