Inspection Status: Partial Approval
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/11/2003 |
FRAMING |
|
Partial Approval |
FIRE STOP FURNACE ROOM AND CLOSET OK TO SHEET ROCK EXCEPT FOR CLOSET AND FURNACE ROOM |
| 02/25/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) COMPLY WITH HEADER SCHEDULE-ALL FRAME MEMBERS SHALL BE ON EDGE 2) REMOVE ALL INSULATION FOR INSPECTION 3) REMOVE DRYWALL NAILS FROM H2.5'S AND USE TICO NAILS 4) HAVE LICSENSE ELECTRICIAN COMPLETE WORK 5) PROTECT ALL PIPES AND WIRES CLOSER THAN 1 1/4" FROM FACE OF STUDS 6) GET QUALIFIED PLUMBER TO CHECK ALL PLUMBING AND TEST ABS TOP OUT 7) FIRE BLOCK MISSING THRU-OUT 8) TRIMMER STUDS REQUIRED UNDER HEADERS |
| 11/14/2001 |
FRAMING |
|
Not ready for Inspection |
1) PLAN CALLS FOR 2 X 6 CEILING JOIST AT 24" YOU HAVE 2 X 4 AT 24" ON CENTER ( MAYBE OK IF YOU INSTALL 2 X 8 AT 16" ON CENTER FOR RAFTERS INSTEAD OF 24" ON CENTER YOU CAN KEEP THE 2 X 4 CEILING JOIST AND USE A STIFF LEG 2) MECHANICAL DUCTS METAL FITTINGS, NEED TO HAVE A RIB AROUND THE ENDS TO KEEP THE DUCT FROM SLIDING OFF |
| 10/29/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NO ACCESS TO SITE 2) TWO DOGS IN YARD |