Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T00CM05645
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/21/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
02/15/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ STUDS NOTCHED TOO DEEP CONDENSATE LINE. | |
02/13/2001 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/1. NO H20 TEST 2. BLOCK DUCT WORK GARAGE. 3. STUD'S NOTCHED TOO DEEP CONDENSATE LINE. 4. HANGERS AT GIRDER TRUSS NEED MORE NAILING ADD 2 X 4 FLAT TO TOP OF GIRDER. 5. ADD A BLOCK UNDER WINDOW FRONT ENTRY 6. NEED FULL BEARING SHIMS AT REAR SLIDER GLU LAM 7. SHEAR WALLS NOT ANCHORED PER PLAN. 8. FURR OUT AT TUB 9. NEED TO START BLOCKING AND NAILING ROOF AT EXT. WALL, CUT BLOCKS TO FIT 9. GAS TEST OK. |