Permit: T00CM05645

Parcel: 136260920


Addresses:

3173 S QUINN DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T00CM05645

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/21/2001 FRAMING Approved IVRS - Inspection 0000*
02/15/2001 FRAMING Denied IVRS - Inspection 0999*/ STUDS NOTCHED TOO DEEP CONDENSATE LINE.
02/13/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*/1. NO H20 TEST 2. BLOCK DUCT WORK GARAGE. 3. STUD'S NOTCHED TOO DEEP CONDENSATE LINE. 4. HANGERS AT GIRDER TRUSS NEED MORE NAILING ADD 2 X 4 FLAT TO TOP OF GIRDER. 5. ADD A BLOCK UNDER WINDOW FRONT ENTRY 6. NEED FULL BEARING SHIMS AT REAR SLIDER GLU LAM 7. SHEAR WALLS NOT ANCHORED PER PLAN. 8. FURR OUT AT TUB 9. NEED TO START BLOCKING AND NAILING ROOF AT EXT. WALL, CUT BLOCKS TO FIT 9. GAS TEST OK.