Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/24/2001 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000* |
| 01/18/2001 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection 0000*/TUB AND SHOWER REQUIRE SAN "T" NOT COMBUS OK TO BOX OUT AND CHECK AT PRE SLAB OK TO CONTINUE. |
| 01/11/2001 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0305*/1. DRAIN AND SEWER LINE MUST BE CONTINOUSLY SUPPORTED ON AND UNDISTUBED OR COMPACTED NATURAL SOIL OR FILL. 2. FLAT AND REVERSE FLOW ON 2" DRAIN 1/4" PER FOOT SLOPE REQUIRED. 3. SANITARY T VENT FITTING NOT ALLOWED HORIZONTAL DRAIN OR SEWER AT CONNECTION TO EXISTING. 4. TUB AND SHOWER NOT PROPERLY VENTED. 5. WATER CLOSET NOT PROPERLY VENTED. YOU MUST BUILD TO PLAN. |