Permit: T00CM05642

Parcel: 112060720


Addresses:

2636 N GILL AV

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
02/22/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
02/02/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. 1/S2 OF YOUR PLAN REQUIRES 1/2" O.S.B. SHEATHING ON EXTERIOR 2 X 4 FRAME AT 16" O.C. YOU MUST BUILD TO PLAN OR REVISE PLAN TO AS BUILT. AS BUILT YOUR ADDITION IS NOT PROPERLY BRACED PER SECTIONS 2326.4.2 AND 2326.11.3 OF THE UNIFORM BUILDING CODE. 2. YOU MUST PROVIDE A HEADER FOR THE BATHROOM GLASS BLOCK IF YOU INTED TO REMOVE ANY STUD.