Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/26/2001 FRAMING Approved IVRS - Inspection 0000*
01/25/2001 FRAMING Partial Approval IVRS - Inspection 0000*/1. PROVIDE AN APPROVED METHOD FOR SECURING GAS LINE AND WATER LINES PROTECT VERTICALLY AND HORIZONTALLY WITHIN 1 1/4 FROM EDGE OF STUDS SAME FOR ELECTRICAL. 2. PROVIDE FHA'S AT ALL OVER BORED EXTERIOR AND INTERIOR ENGINEERED WALLS. 3. PROVIDE 50 PSI FOR WATER TEST.
01/19/2001 FRAMING Denied 1. FIRE PLACE NOT INSTALLED. 2. NEGATIVE SLOPE AT MASTER LAV. 3. PROVIDE CLEARANCE AT REFRIGERANT LINE FROM FHA. 4. GROUT TUBS.