Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T00CM05627
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/22/2001 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
02/20/2001 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/RELOCATE OUTLET SEAL HOT WATER HEATER FLUE PENETRATION IN GARAGE. | |
02/16/2001 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/1. SEAL PENETRATION AT REFRIGERANT LINE. 2. COUNTER TOP AT INSLAND PENNISULA EXCEEDS 6" RELOCATE RECEP TO WITHIN 6" OF SIDE. 3. NO PLANS ON SITE. 4. PROVIDE ACCESS TO ATTIC INSPECTION. | |
02/15/2001 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/1. NO GFI IN GARAGE. 2. NO BACKFLOW ON SOUTH HOSE BIB 3. NO A/C FUSES. 4. MOVE A/C AWAY FROM DISCONNECT. 5. EXPOSE THE CLEANOUTS. |