Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/05/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/16/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/BREAK THRU NOT IN |
| 01/11/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. WIRES STAPLED TOO TIGHT SHEATHING CRUSHED. EDGE NAILING NOT ALLOWED. 2. NAIL SILL PLATE AT 12" O.C. W. 1-16D MINIMUM. 3. NAIL PROTECT PEX BY MANO BLOCK. 4. MAKE UP ALL GROUNDS. 5. SUPPORT 3" ABS DRAIN AT MISSION COUPLING AND 4' O.C. 6. STRAP DUCT ELBOW FOR FULL FLOW. |
| 12/20/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/PLUMBING CHANGES NEEDED FOR VENTS. NEEDS TO BE LEVELED AND FILLED FOR TEST. |