Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T00CM05600
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/21/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
02/15/2001 | FRAMING | Denied | IVRS - Inspection 0999*/1. STUDS IN BEARING WALLS MUST NOT BE NOTCHED OVER 25% (ITEM 5 ABOVE) 2. ITEMS 7 & 8 ABOVE DO NOT APPEAR TO BE DONE. | |
02/13/2001 | FRAMING | Denied | 1. REPLACE BLOCKS KNOCKED OUT BY PLUMBER AT GARAGE SHEAR WALL (FLAT) IS OK 2. TRUSS TO GIRDER TRUSS INSTALL CORRECT NAILS AT HANGERS, PULL OUT ALL BENT OVER NAILS, DRIVE HOME NAILS THAT ARE NOT. 3. STRAP ACCROSS DRYER DUCT. 4. NEGATIVE PITCH CONDENSATE LINE A W/H PLATFORM (SECURE IT). 5. NOTCHES CUT IN 2 X 4 ARE TOO DEEP. 25/40% IS THE MAXIMUM BEARING NON-BEARING SHEAR WALL? 6. LOW GAS PRESS TEST. 7. INSTALL PLYWOOD BEHIND W/H PLATFORM TO COMPLETE SHEAR WALL. 8. SHEAR PANELS NOT NAILED TO ROOF. 9. EXHAUST FAN DAMPER WON'T WORK M/BATH, MISSING END BATH 10. NEED TO TALK TO SUPT. |