Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T00CM05565
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/23/2000 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000* ABS UNDERGROUND OK TRANSITION FITTINGS OK WATER TEST OK DWV PIPING OK COPPER PIPING OK I STILL NEED TO SEE CONDENSATE PIPING OK TO COVER EVERYTHING ELSE |
|
11/21/2000 | PLUMBING - ROUGH, SOIL | Denied | BREAKROOM COMBO ON FLOOR SINK LOWERS POINT OF VENT BELOW WEIR OF TRAP USE SANTEE N/H BANDS ARE NOT APPROVED FOR CONNECTING ABS USE SHIELDED COUPLING (MISSIUN) AT FLOOR SINK AND WHERE TIED INTO MAIN VTR OK |