Permit: T00CM05548

Parcel: 137337090

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/11/2001 FRAMING Approved IVRS - Inspection 0000*
01/10/2001 FRAMING Partial Approval IVRS - Inspection 0000*/1. PROTECT ELEC ROMEX WITHIN 1 1/4 FROM EDGE OF STUDS. 2. PROVIDE WATER TEST. 3. NAIL SHEARWALL TRANSER AS PER PLAN. 4. PROVIDE DETAIL 15/SD3 5. SHEARWALL DBL TOP PLATE PROVIDE STT OR COIL STRAP.
01/08/2001 FRAMING Denied IVRS - Inspection 0999*/1. NO UFER 2. SHEAR TRANSFERS NOT COMPLETE SEE SD3/18, SD3/17. 3. FRAMER'S ON SITE. 4. OVERKNOTCHED SHEAR TRANSFER PROVIDE ENGINEERS FIX. 5. DRY/SEAL FROM INFILTRATIONS ALL PENETRATIONS AT SOLE PLATES AS PER PLAN. 6. DRAFTSTOP/FIRE BLOCKS NOT COMPLETE. 7. NO TEST ON PEX LINES. NOTE: OVERKNOTCHES ARE COMMON ON K & B SITES SUPERINTEDENTS NEED TO BE AWARE OF ENGINEER'S REPAIRS A RE-INSPECTION FEE WILL BE IMPOSED NEXT INSPECTION WITH SAME RESULTS.