Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T00CM05547

Parcel: 137337110

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
01/10/2001 ROOF NAILING Approved IVRS - Inspection 0000*
01/08/2001 ROOF NAILING Denied 1. SEE MANF. INSTALLATION STANDARDS FOR ROOF SHEATHIN PANELS, NOT INSTALLED AS PER SPEC'S. 2. LOTS OF SHINERS LOOSE PANELS THRU OUT 3. PROVIDE COT APPROVDE ON ALL TRUSS CALC'S 00015 INSPECTIONS AND 00035.