Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/17/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/16/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/OK TO INSULATE. 1. BLOCK UNDER HIP AT BEARING WALL. 2. PROVIDE ENGINEERED AND C.O.T. APPROVED TRUSS CALC'S FRONT GABLE END TRUSS NEEDS WEBS 16" O.C. FOR VERTICAL RE-ENFORCEMENT AT OUT LOOKERS. 3. PROTECT ELECTRIC ROMEX THRU-OUT WITHIN 1 1/4 FROM EDGE OF ALL STUDS AND AT AC LINE WIRE. 4. REFRIGERANT LINE STRESSED BY FHA STRAP PROVIDE CLEARANCE, DISSIMILIAR METALS SHOULD NOT BE TOUCHING ISOLATE. 5. SECURE PVC CONDENSATE LINES 4' O.C. HORIZONTALLY. |