Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/29/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/23/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/OK ALL EXCEPT SWS SHEAR AND 2 X 12 HEADER SUPPORT. |
| 01/19/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/1. NEED SUPPORT AT 2 X 12 HEADER BRING VERTICAL SUPPORT DOWN TO SLAB. 2. BOLT BOTTOM PLATE TO SLAB #5 SHEAR WALL. FINISH ALL REPAIRS FOR THESE TWO ITMES. ALL OTHER TRADES OK. |
| 01/12/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/1. MISSING DAMPER IN EXHAUST FAN IN REAR BATH. 2. SHED ROOF RAFTERS TOO BE 16" O.C. PER PLAN 3. ADD 2 X 4 CIELING JOIST AT TUB CENTER BATH. 4. BLOCK GAS LINE WHERE IT EXISTS THE WALL H20 HEATER 5. HEADER 2 X 12, NEED, A KING STUDS UNDER CENTER SUPPORT PLUS SHEAR WALL SW5 NOT INSTALLED UNDER SAME HEADER. |