Permit: T00CM05486

Parcel: 137337100

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/11/2001 FRAMING Approved IVRS - Inspection 0000*
01/08/2001 FRAMING Denied IVRS - Inspection 0999*/1. PROVIDE CLEANOUT AT CHICAGO LOOP FOOT VENT. 2. PROCIDE 3 NIALS PER SIDE OF 16 GA FHA STRAP SEE UBC CHAP 23. 3. SECURE DBL TOP PLATES AT GARAGE BACK SHEARWALL TANSFER. 4. PROTECT REFRIGERANT LINE INSPECTION STOPPED SUPERINTENDENT IS AGAIN ADVISED TO WALK HOUSE BEFORE CALLING FOR INSPECTIONS CANNOT PROVIDE A PUNCH LIST. 5. REMOVE LOW VOLTS FROM HIGH VOLT BOX. 6. TRENCH NEEDS TO BE CLEAN OUT PROVIDING 24" DEPTH FOR CABLE DROP.