Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 04/13/2001 |
PLUMBING - GAS PRESSURE TEST |
|
Approved |
IVRS - Inspection 0000* |
| 04/03/2001 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0999*/1. THIS HOUSE HAS BEEN REWIRED NEW MECHANICAL DUCTWORK, "O" CLEARANCE FIREPLACE INSTALLED MECHANICAL UNIT REPLACED. 2. FIREPLACE GAS LOG IMPROPERLY INSTALLED. 3. INCORRECT GAS VALUE AT FIRE PLACE. 4. INADEQUATE ATTIC ACCESS. YOU MUST OBATIN A DOUBLE FEE PERMIT FOR ALL OWRK PERFORMED ON HOUSE. |
| 03/21/2001 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0999*/1. FLEXABLE GAS CONNECTION CANNOT PENETRATE WATER HEATER ENCLOSURE. 2. NO PRESSURE TEST ON GAS LINE. 3. HOUSE LOCKED UNABLE TO INSPECT INTERIOR APPLIANCES. 4. 6" CLEARANCE REQUIRED TO COMBUSTABLE MATERIAL AT ROOF FROM SINGLE WALL WATER HEATER VENT OK IF DOUBLE WALL VENT INSTALLED THEN 1" TO COMUBSTABLE. 5. PROVIDE WATER HEATER REPLACEMENT PERMIT AND PERMITS FOR ANY OR ALL OF WORK DONE TO THIS HOUSE. |
| 11/09/2000 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0999* |