Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 12/04/2000 |
ELECTRIC - RECONNECT |
|
Approved |
IVRS - Inspection 0000* |
| 12/01/2000 |
ELECTRIC - RECONNECT |
|
Denied |
NEED TO EXPOSE GROUND RODS TO VERIFY CORRECT CONNECTION. |
| 11/09/2000 |
ELECTRIC - RECONNECT |
|
Denied |
IVRS - Inspection 0999*/1. WATER HEATER NOT PROPERLY INSTALLED. 2. ELECTRIC SERVICE NOT PROPERLY GROUNDED. INSTALL 2 EACH 8FT. GROUND RODS. A MINIMUM OF 6 FEET APART. CONNECTED TO SERVICE PANEL WITH A CONTINUOUS #4 GROUND WIRE. 3. NONE OF THE GAS FIRE AND HEATING APPLIANCE MEET CODE DUE TO TYPE, LOCATION OR CONDITION. 4. HOUSE HAS NO HEAT AND IS NOT HABITABLE IN PRESENT CONDITION. |