Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T00CM05459
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/07/2001 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000* OK FOR C OF O | |
03/06/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999* 1) PLUMBING CONTRACTOR SCREWED IN A C.O. COVER PLATE TO DRYWALL WITH NO C.O. THIS IS TOTALLY UNACCEPTABLE. MUST PROVIDE C.O. AS PER APPROVED DRAWING 2) EXPANSION TANK AT WATER HEATER MUST HAVE PROPER TRANSISTION EITHER A DIELELECTRIC UNION OR BRASS NIPPLE AND COUPLING CAN BE USED 3) EXPANSION TANK IS ALSO LEAKING 4) MUST PAY RE FEE BEFORE NEXT INSP. 5) MUST REMOVE ALL C.O. COVER PLATES INSIDE BLDG PRIOR TO INSP. | |
03/02/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999* 1) WATER HEATER MUST HAVE EXPANSION TANK 2) WATER HEATER RECERC. LINE SHOWS CHECK VALVE IN LINE. MUST INSTALL AS PER PLAN 3) MUST EXPOSE AND EXTEND C.O FOR L-1, WASHER BOX, SK-2 4) REVERSE OSMOSSIS IS NOT INSTALLED TO COPE 5) MUST SEE FINAL CONNECTION TO STEAM GENERATORS 6) P AND T DRAIN MUST HAVE ISOLATORS ON METAL STUDS |