Permit: T00CM05459

Parcel: 110050380


Addresses:

2951 N SWAN RD #111


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T00CM05459

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/07/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000* OK FOR C OF O
03/06/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999* 1) PLUMBING CONTRACTOR SCREWED IN A C.O. COVER PLATE TO DRYWALL WITH NO C.O. THIS IS TOTALLY UNACCEPTABLE. MUST PROVIDE C.O. AS PER APPROVED DRAWING 2) EXPANSION TANK AT WATER HEATER MUST HAVE PROPER TRANSISTION EITHER A DIELELECTRIC UNION OR BRASS NIPPLE AND COUPLING CAN BE USED 3) EXPANSION TANK IS ALSO LEAKING 4) MUST PAY RE FEE BEFORE NEXT INSP. 5) MUST REMOVE ALL C.O. COVER PLATES INSIDE BLDG PRIOR TO INSP.
03/02/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999* 1) WATER HEATER MUST HAVE EXPANSION TANK 2) WATER HEATER RECERC. LINE SHOWS CHECK VALVE IN LINE. MUST INSTALL AS PER PLAN 3) MUST EXPOSE AND EXTEND C.O FOR L-1, WASHER BOX, SK-2 4) REVERSE OSMOSSIS IS NOT INSTALLED TO COPE 5) MUST SEE FINAL CONNECTION TO STEAM GENERATORS 6) P AND T DRAIN MUST HAVE ISOLATORS ON METAL STUDS