Permit: T00CM05458

Parcel: 12312207A


Addresses:

1001 E EDISON ST


Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Permit Number - T00CM05458

Inspection Description - PLUMBING - SEWER HCS CONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
03/12/2001 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection 0000*
03/08/2001 PLUMBING - SEWER HCS CONNECT Denied IVRS - Inspection 0999*/1. THE CONNECTION TO THE EXISTING SEWER IS NOT MADE. 2. YOU MUST HAVE A WATER TEST OF ALL UNDERSLAB PLUMBING TO INCLUDE THE NEW SHOWER AND WATER CLOSET. THE WATER TEST MUST BE MADE WITH A WATER COLUMN AT LEAST 42" ABOVE THE FINISHED FLOOR OF THE ADDITION. PRESENTLY YOU HAVE ONLY WATER IN THE DRAIN TRUNK LINE. 3. I AM UNABLE TO LOCATE YOUR EAST SIDE PROPERTY LINE PLEASE RE-ESTABLISH THE N.E. CORNER PIN. 4. YOU WILL NEED TO ESTABLISH A GROUND SYSTEM FOR THE NEW GARAGE. I RECOMMEND A UFER GROUND CONNECTIONS TO A 20 FOOT REBAR WITH #4 CU. CONDUCTOR.
03/07/2001 PLUMBING - SEWER HCS CONNECT Denied IVRS - Inspection 0999*