Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 04/13/2001 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000* |
| 04/12/2001 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection 0000*/ALL BELOW FINISHED FLOOR LEVEL OK BUT STATIONARY "T" FITTING IN LAVITORY DRAIN NOT ALLOWED IT MUST BE A DIRECTIONAL FITTING, ALSO THE 3" TO 2" "COMBO" FITTING IN LAVITORY DRAIN AT THE VENT STACK MAKES THE VENT OPENING LOWER THAN THE TRAP WIRE, YOU MAY REPLACE THE "COMBO" OR RE VENT THE LAV DRAIN NOTE: GARAGE FLOOR OK TO POUR, NOT BATHROOM |