Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T00CM05455
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/23/2002 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*1.) ALL CORRECTIONS MADE OK 2.) PLUMBING FINAL OK 3.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS 4.) UCC LEFT AT METER. | |
01/21/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) A WOOD SCREW OR LAG BOLT SCREWED INTO AN ABS CO PLUG IS NOT APPROVED USE TAPPED CO PLUG WITH APPROVED SCREW. 2.) A CONDENSATE DRAIN MAY NOT BE DIRECTLY TAPPED INTO AN ABS TAP ARM. REMOVE DRAIN, REPAIR TRAP ARM, AND CALL FOR INSPECTION BEFORE COVERING. | |
11/29/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) PLEASE READ NOTE NUMBER TWO ON TOOCM05456. 2.) EXPOSE ALL PIPING AND FITTINGS AND CALL FOR INSPECTION. | |
11/28/2001 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection 0000*1.) NOT READY FOR INSPECTION. | |
11/07/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) NO ADDRESS POSTED 2.) NO PLAN ON SITE 3.) HAVE YOUR PLUMBER WALK THROUGH THIS JOB TO INSURE IT IS READY FOR INSPECTION. |