Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/08/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 01/05/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1. PATIO ROOF NOT NAILED. 2. PLANS CALL FOR FH STRAPS ON HEADERS INSTALLED ON THE DIAGONAL. 3. STRAP REAR TOP PLATES WHERE THEY ARE NOT CABIN TIED. 4. MISSING STUD CLIPS REAR CORNER. 5. INSTALL ALTERNATE HOLDOWN AT REAR SHEARWALL. 6. MISSING HEADER CONNECTION AT PATIO WINDOW 7. TCI CLIPS MISNAILED. 8. SHIM CRIPPLES WHERE NEEDED. |
| 01/03/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Cancelled |
IVRS - Ri canceled |