Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 05/31/2001 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*1)ALL CORRECTIONS MADE OK.2)CLOSET FLANGES OK.3)TUBS OK.4)OK TO COVER WALLS. |
| 05/29/2001 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1)ABS DWV PIPING WATER TESTED RISERS ONLY ON ROUGH/SOIL-PLUMBER IN,TRAP ARMS,CLEANOUTS,STAND PIPES FOR CLOTHES WASHERS, COUPLINGS, AND STAB OUTS FOR LAVATORIES.NEED TO SEE WATER TEST TO 42".2)TRAP ARM MAY NOT CHANGE SIZE.3)707.6 94 UPC CLEAN-OUTS TO BE INSTALLED OR VERTICAL PIPING-NOT IN THE MIDDLE OF A TRAP ARM. |