Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T00CM05381
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/29/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
01/25/2001 | FRAMING | Denied | IVRS - Inspection 0999*/1. CONDENSATE LINES NOT PITCHED FOR PROPER DRAINAGE. 2. HANGERS ABOVE STAIRWAY NOT PER PLAN SHOULD BE LUS 210-2. 3. REPAIR TORN FLEX DUCT. 4. INSTALL BANG PLATES OVER ROMEX NOTCHED INTO STUDS UPSTAIRS. | |
01/24/2001 | FRAMING | Denied | IVRS - Inspection 0999*/1. LOOSE ANCHOR BOLTS IN GARAGE. 2. UN-NAILED CLIP ON GARAGE REAR TRUSS. 3. NO GAS PRESSURE. 4. NO WATER PRESSURE. 5. PLUMBING INCOMPLETE. 6. CORRECT PITCH OF CONDENSAT LINES. 7. SECURE GAS PIPING AT ATTIC MECHANICALS 8. INSTALL MID-SPAN CROSS BRACING. |