Permit: T00CM05381

Parcel: 141113150

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T00CM05381

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/29/2001 FRAMING Approved IVRS - Inspection 0000*
01/25/2001 FRAMING Denied IVRS - Inspection 0999*/1. CONDENSATE LINES NOT PITCHED FOR PROPER DRAINAGE. 2. HANGERS ABOVE STAIRWAY NOT PER PLAN SHOULD BE LUS 210-2. 3. REPAIR TORN FLEX DUCT. 4. INSTALL BANG PLATES OVER ROMEX NOTCHED INTO STUDS UPSTAIRS.
01/24/2001 FRAMING Denied IVRS - Inspection 0999*/1. LOOSE ANCHOR BOLTS IN GARAGE. 2. UN-NAILED CLIP ON GARAGE REAR TRUSS. 3. NO GAS PRESSURE. 4. NO WATER PRESSURE. 5. PLUMBING INCOMPLETE. 6. CORRECT PITCH OF CONDENSAT LINES. 7. SECURE GAS PIPING AT ATTIC MECHANICALS 8. INSTALL MID-SPAN CROSS BRACING.