Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 05/02/2001 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Approved |
IVRS - Inspection 0000*/ 1) BARE BULB LIGHT FIXTURE NOT ALLOWED IN CLOSET 2) A BATTERY OPERATED SMOKE DETECTOR REQ'D IN BEDROOM AND IN LAUNDRY 3) FLEX VENT CONNECTOR NOT ALLOWED ON WATER HEATER 4) MAKE REPAIRS AND CALL FOR FINAL INSP |
| 03/26/2001 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/1. INADEQUATE FOOTING UNDER ADDITION. YOU MUST EXAVATE A MINIMUM OF 12" BELOW GRADE AND 12" UNDER. ADDITION AND INSTALL 2 EACH #4 REBAR AROUND ENTIRE ADDITION WITH REBAR 3" ABOVE SOIL AND SEPARATED A MINIMUM OF 3" APART CALL FOR INSPECTION WHEN INSTALLED AND PRIOR TO PLACING CONCRETE. |
| 03/22/2001 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/NEED APPROVED DRAWINGS ON SITE. 2. MAKE APPOINTMENT WITH FIELD INSPECTIOR TO MEET ON SITE. |
| 03/20/2001 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/EXCAVATE ONE LOCATION ON SOUTH FOOTING TO A DEPTH OF 14" FOR FOOTING INSPECTION. |