Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/11/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/10/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ALL CORRECTIONS NOT COMPLETE. LET THIS BE THE LAST TIME YOU CALL FOR INSP. PRIOR TO CORRECTIONS. NEXT TIME A RE-FEE WILL BE ASSESSED. |
| 01/09/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. MISSING BOLT AT H.D. 2. MISSING F/BLOCKING 2. HANGER AT HIP JACK 1ST FL. BEDROOM AND GARAGE. 3. HANGER AT TRUSSED ABOVE KITCHEN NOT NAILED. 4. F/BLOCKING AT 2ND FLOOR BEDROOM S.E. CLOSET AND FRONT ON BOTH BEDROOMS. SUPER NEEDS TO WALK JOB. |