Permit: T00CM05266

Parcel: 123081050


Addresses:

2618 E MABEL ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
05/21/2001 BUILDING - FINAL Approved IVRS - Inspection 0000*
05/17/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) ABS PLASTIC VENTS ON ROOF MUST BE PROTECTED WITH LATEX PAINT 2) A GAS SHUT OFF VALVE IS REQUIRED UPSTREAM OF UNION 3) A/C CONDENSOR BLOCKS DISCONNECT 4) WATER HEATER T/P LINE MUST EXHAUST DOWN 5) SECURE GAS LINE BY FURNACE 6) BARE BULB LIGHT FIXTURE NOT ALLOWED IN CLOSET 7) BATTERY OPERATED SMOKE DETECTORS REQUIRED IN EXISTING BEDROOMS