Permit: T00CM05259

Parcel: 133262970


Addresses:

601 N SARNOFF DR

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
05/24/2001 BUILDING - FINAL Approved IVRS - Inspection 0000*
05/23/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) FURNACE FLUE TO CLOSE TO COMBUSTIBLE 2) SEAL PENETRATIONS AT CEILING
05/11/2001 BUILDING - FINAL Partial Approval IVRS - Inspection 0000*/ 1) NEED INSULATION AND STUCCO CERTIFICATES 2) COMPLETE GRADING 3) PAINT EXPOSED PLUMBING VENTS ON ROOF LATEX PAINT 4) BONDING JUMPER ACCROSS NON METALLIC DUCT WORK 5) INSTALL MINIMUM 1" STAND OFFS NON COMBUSTIBLEAT SHEET METAL FURNACE FLUE PIPES 6) CONNECT DISHWASHER DRAIN HOSE TO UNDERSIDE OF COUNTER TOP 7) LAV TO CLOSET TOILET
05/08/2001 BUILDING - FINAL Denied IVRS - Inspection 0950*/ NOT READY FOR INSPECTION
05/07/2001 BUILDING - FINAL Not ready for Inspection 1) NEED HOUSE (# ADDRESS) 2) BLANK IN SERV PANEL 3) OFF/ON EXT OUTLETS, LABEL BREAKER 4) PVC ARMOR FLEX NEXT TO SINGLE WALL FURN FLUE 5) GFCI LEFT SIDE WON'T TRIP 6) RAISE DISPOSAL LINE ABOVE F/RIM 8) FIRE CAULK LOG LITER 9) LAV TOO CLOSE TO TOILET 13" TO CL