Permit: T00CM05211

Parcel: 12501077A


Addresses:

2760 E 8TH ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/25/2001 FRAMING Approved IVRS - Inspection 0000*
04/03/2001 FRAMING Partial Approval IVRS - Inspection 0000*
04/02/2001 FRAMING Cancelled IVRS - Ri canceled
04/02/2001 FRAMING Cancelled IVRS - Ri canceled
03/13/2001 FRAMING Denied IVRS - Inspection 0999*
03/06/2001 FRAMING Denied IVRS - Inspection 0999*/1. FILL ALL ROUND HOLES IN SIMPSON HARDWARE WITH PROPER NAILS. 2. SECURE ALL GROUND WIRES IN ELECTRIC BOXES AND SECURE WITH A MECHANICAL FASTENER. PROVIDE GROUND PIT TAIL FOR ALL OUTLETS AND SWITCHES. 3. ALL WIRES MUST TERMINATE IN APPROVED ELECTRIC BOXES. 4. EXPOSE PAHD HOLD DOWNS FOR INSPECTION OF NAILING. 5. NAIL ENDS AND EDGES OF SHEATHING ON WALLS AT 8" MAX O.C. 12" IN FIELD. 6. SECURE ENDS AND SUPPORTED EDGES OF ROOF SHEATHING AT 6" O.C. MAX AND FIELD 12" O.C. 7. ALL SPLICES ON BOTTOM OF DOUBLE TOP PLATE MUST LAND ON A SUPPORTING MEMBER (STUD).