Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/28/2000 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/27/2000 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/1. FHA STRAP DBL TOP PLATE AT GAS LINE. 2. NAIL SHEAR AT GARAGE OSB EDGE VERTICAL. 3. PROTECT ELEC. WITHIN 1 1/4" FROM EDGE OF STUD. 4. PROVIDE POSITIVE CONNECTION DBL TOP PLATE GARAGE EAST SHEARWALL. ANCHOR BOLT WITHIN 12" OF SPLICE AT SOLE PLATE. 5. PROTECT PLUMBING COPPER AT HOT WATER DBL TOP PLATE. 6. DRAFTSTOP KITCHEN NICHE 1" MINIMUM. 7. PROVIDE TEST ON PEX LINES. |