Permit: T00CM05138

Parcel: 125075710


Addresses:

333 N PLUMER AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/16/2001 FRAMING Approved IVRS - Inspection 0000*
02/13/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*/3. W/C FLOOR FLANGES NOT INSTALLED. 4. SEAL FLOOR OF FURNACE PLENUIM. 5. THREE BEARING STUDS IN KITCHEN WALL HAVE OVER BORED STUDS DOUBLE UP WITH NEW. 6. INSULATION BAFFELS NOT INSTALLED SEE 8/7. 7. HIP HANGERS MUST BEAR HIP TRUSSES SHIM. 8. DOUBLE GIRDER TRUSS ABOVE KITCHEN MUST BEAR ON 4 X 4 MINIMUM NOT ON BOX BEAMS.
01/16/2001 FRAMING Denied IVRS - Inspection 0950*/NOT COMPLETE ENOUGH TO INSP. NOTE: YOU MUST PROVIDE UNDER FLOOR CROSS VENTILATION FLOOR JOIST HANGERS OK.