Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/16/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 02/13/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/3. W/C FLOOR FLANGES NOT INSTALLED. 4. SEAL FLOOR OF FURNACE PLENUIM. 5. THREE BEARING STUDS IN KITCHEN WALL HAVE OVER BORED STUDS DOUBLE UP WITH NEW. 6. INSULATION BAFFELS NOT INSTALLED SEE 8/7. 7. HIP HANGERS MUST BEAR HIP TRUSSES SHIM. 8. DOUBLE GIRDER TRUSS ABOVE KITCHEN MUST BEAR ON 4 X 4 MINIMUM NOT ON BOX BEAMS. |
| 01/16/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0950*/NOT COMPLETE ENOUGH TO INSP. NOTE: YOU MUST PROVIDE UNDER FLOOR CROSS VENTILATION FLOOR JOIST HANGERS OK. |