Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 12/31/2001 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 09/04/2001 |
ELECTRIC - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000* |
| 08/23/2001 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1.) PROTECT WIRES IN METAL BOXES 2.) ELETRIC OUTLETS REQUIRED WITHIN 6" OF DOORS & 12" THEREAFTER 3.) PROVIDE PROOF OF SPECIAL INSPECTION 4.) VARITY STAIR HEAD RISER. 5.) ELECTRIC NOT ALLOWED IN PLENIUM 6.) CONDENATE NOT PROPERLY TERMINATED 7.) HOLES IN STEEL STUDS EXCEED 1 1/2 X 4 1/2 PROVIDE ENGINEERING APPROVED REPAIR. 8.) WALL TRACKS NOT PROPERLY ANCHORED. REINFORCE WITH STUD 9.) BOND/AROUND WIRE IN CONTACT WITH DISSIMILAR METAL. 10.) SHOWER NOT PROPERLY VENTE 11.) LPI AT GARAGE REQ HANGER 12.) ROOF JOISTS MISSING SCREWS. 13.) 2ND FLOOR SHGAR WALL STUDS CUT |
| 08/21/2001 |
ELECTRIC - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000* |