Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/31/2001 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 11/26/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) CLEANOUTS MUST BE READILY ACCESSIBLE 2) PROVIDE 2 PERCENT GRADE AWAY FROM BUILDING FOR 5'-COMPLETE ALL GRADING 3) UNTREATED LUMBER OF BRIDGE CANNOT BE WITHIN 6" OF SOIL4) STOOP REQUIRED AT S/G DOOR WITH ON CENTER 36" DEEP 5) FILL GAPS IN WEST WALL UPSTAIRS 6) HAND RAIL TO SMALL IN DIAMETER 1 1/4 MINIMUM 2" MAXIMUM AND NOT PROPERLY SUPPORTED. HAND MUST NOT BE REQUIRED TO BE REMOVED TO DECEND AND HAND RAIL MUST RETURN TO SUPPORT PER UBC 1006.9 7) FILL GAP IN GARAGE TO HOUSE FIRE DOOR |
| 11/23/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) GFCI AT COURTYARD WALL NOT WORKING 2) GFCI AT DISCONNECT WILL NOT TRIP 3) EXHAUST FAN IN MASTER BATH NOT WORKING |