Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
06/19/2001 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection 0000*
06/07/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*/ 1) PARTIAL TO BOTTOM OF ROOF LEDGER
06/04/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*/ 1) ALL OK BUT LAST LIFT, BOND BEAM AND EXPANSION JOINTS 2) 2ND FLOOR PERLIN ANCHORS OK
05/24/2001 REINFORCED MASONRY PRE-GROUT Not ready for Inspection CANCELLED
05/23/2001 REINFORCED MASONRY PRE-GROUT Partial Approval
05/16/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*/ 1) ITEM 5 CONTROL JOINTS NOT INSTALLED BUILD TO PLAN OR REVISE PLAN TO AS BUILT AND HAVE APPROVED 2) ALL ELECTRICAL OK AT TOP OF FIRST FLOOR
05/11/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*/ 1) 10 COURSES ABOVE F.F. 100
04/19/2001 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*/FIRST LIFT, 6 BLCKS HIGH ON HOUSE 3 EAST WALLS AND PATIO WALL 4 BLCKS HIGH ON N/E AND WEST WALLS
04/18/2001 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection 0999*/1) VERTICAL REBAR MUST BE IN SAME CELLS AS STEM WALL VERTICAL REBAR AND HAVE 40 ROD DIAMETER OVERLAP 2) MANY CELLS ARE BLOCKED OR ARE TO DIRTY TO GROUT 3) NO PLAN/PERMIT ON SITE